PV800-12 S1.2 Solar Inverter
1.2kW output with a 12V battery. The 800W figure is the PV input limit, not the AC output rating.
- MPPT photovoltaic input
- Battery-based energy storage and backup configuration
- Pure sine-wave AC output
PV800-12 S1.2 Solar Inverter
1.2kW output with a 12V battery. The 800W figure is the PV input limit, not the AC output rating.
Product features
- MPPT photovoltaic input
- Battery-based energy storage and backup configuration
- Pure sine-wave AC output
Applications
Solar and battery energy systems. Check AC supply voltage, PV string open-circuit voltage, battery current and the supplied configuration before selection.
Selection & configuration
Match the exact ordering model to the supply, load and site conditions. Consult the model-specific technical data before choosing PV strings, motor equipment or battery settings.
Model rating table
↔ Scroll left or right on small screens to view every column. Focus the table region to use the arrow keys.
| Model | Rated output | Rated AC current | AC output voltage | Battery | Max. PV input power | Max. PV Voc | MPPT range | Max. PV input current | Max. PV charge current | IP rating |
|---|---|---|---|---|---|---|---|---|---|---|
| PV800-12 S1.2 | 1.2 kVA / 1.2 kW | 5.2 A | 208/220/230/240 V (rated 230 V ±5%) | 12 V (10–15 V) | 800 W | 115 V DC | 17–115 V DC | 18 A | 50 A | IP21 |
AC input
| Rated input voltage | 208/220/230/240 V; L+N+PE |
|---|---|
| Input voltage range | 90–280 V (APP/GEN mode); 170–264 V (UPS mode) |
| Input frequency | 50/60 Hz (auto adaptive) |
| Max. AC bypass current | 10 A |
AC output
| Rated capacity | 1.2 kVA / 1.2 kW (derated to 90% when output voltage is set to 208 V) |
|---|---|
| Surge power | 2.4 kVA |
| Output voltage | 208/220/230/240 V |
| Rated output current | 5.2 A |
| Number of AC outputs | 1 |
| Power factor | 1 |
| Output frequency | 50/60 Hz |
| Transfer time | 10 ms (APP/UPS/GEN mode) |
| Waveform | Pure sine wave |
| Overload capacity (battery mode) | 60 s @ 102–110% load; 10 s @ 120–200% load |
| Max. efficiency (battery mode) | 90% @ 12 V DC |
PV / charger
| Solar charger type | MPPT |
|---|---|
| Max. PV input current / power | 18 A / 800 W |
| MPPT operating range | 17–115 V DC |
| PV start-up voltage | 20 V DC |
| Max. PV open-circuit voltage | 115 V DC |
| Max. PV charge current | 50 A |
| Max. AC charge current | 50 A |
| Max. charge current (PV+AC) | 100 A |
Battery
| Nominal battery voltage | 12 V DC (range 10–15 V) |
|---|---|
| Battery type | Lithium and lead-acid |
General
| HMI | LCD |
|---|---|
| Interface | RS485 (optional) / CAN (optional) / RS232 |
| Monitoring | Wi-Fi (optional) |
| Ingress protection | IP21 |
| Operating temperature | −10 °C to 60 °C |
| Relative humidity | 5%–95% (non-condensing) |
| Storage temperature | −15 °C to 60 °C |
| Max. operating altitude | 4000 m (derating above 2000 m) |
| Safety class | I |
Application & Selection
Solar and battery energy systems. Check AC supply voltage, PV string open-circuit voltage, battery current and the supplied configuration before selection.