PV5000-24 S4.0 LV Solar Inverter
4kW low-voltage AC variant: 110/120V input and 100/110/120/127V output. Not a general 230V grid model.
- MPPT photovoltaic input
- Battery-based energy storage and backup configuration
- Pure sine-wave AC output
PV5000-24 S4.0 LV Solar Inverter
4kW low-voltage AC variant: 110/120V input and 100/110/120/127V output. Not a general 230V grid model.
Product features
- MPPT photovoltaic input
- Battery-based energy storage and backup configuration
- Pure sine-wave AC output
Applications
Solar and battery energy systems. Check AC supply voltage, PV string open-circuit voltage, battery current and the supplied configuration before selection.
Selection & configuration
Match the exact ordering model to the supply, load and site conditions. Consult the model-specific technical data before choosing PV strings, motor equipment or battery settings.
Model rating table
↔ Scroll left or right on small screens to view every column. Focus the table region to use the arrow keys.
| Model | Rated output | AC output voltage | Battery | Max. PV input power | Max. PV Voc | MPPT range | Max. PV input current | Max. PV charge current | IP rating |
|---|---|---|---|---|---|---|---|---|---|
| PV5000-24 S4.0 LV | 4 kVA / 4 kW | 100/110/120/127 V (input 110/120 V) | 24 V | 5000 W | 500 V DC | 60–450 V DC | 18 A | 100 A | IP21 |
AC input
| Rated input voltage | 110/120 V; L+N+PE |
|---|---|
| Input voltage range | 90–140 V (APP/GEN/UPS mode) |
| Input frequency | 50/60 Hz (auto adaptive) |
AC output
| Rated capacity | 4 kVA / 4 kW (output power is reduced if output voltage is set to 100/110 V; output current limited to 33 A) |
|---|---|
| Surge power | 8 kVA |
| Output voltage | 100/110/120/127 V |
| Power factor | 1 |
| Output frequency | 50/60 Hz |
| Transfer time | 10 ms (APP/UPS mode) / 20 ms (GEN mode) |
| Waveform | Pure sine wave |
| Overload capacity (PV+battery / PV mode) | 1 min @ 102–120% load; 10 s @ 120–200% load |
| Overload capacity (bypass mode) | 1 min @ 40–50 A; 10 s @ 50–55 A; 200 ms @ >55 A |
| Max. efficiency (battery mode) | 92.6% |
PV / charger
| Solar charger type | MPPT |
|---|---|
| Max. PV input current / power | 18 A / 5000 W |
| MPPT operating range | 60–450 V DC |
| PV start-up voltage | 70 V DC |
| Max. PV open-circuit voltage | 500 V DC |
| Max. PV charge current | 100 A |
| Max. AC charge current | 100 A |
| Max. charge current (PV+AC) | 100 A |
Battery
| Nominal battery voltage | 24 V DC |
|---|---|
| Battery type | Lithium / lead-acid |
Derating
| Max. load, battery only | 4000 W @ 26.7 V |
|---|---|
| Max. load, PV + battery | 4000 W |
| Bypass current | 40 A @ 25 °C |
General
| HMI | LCD |
|---|---|
| Interface | RS232 / RS485 / CAN / dry contact / CT (optional) |
| Monitoring | Wi-Fi (optional / built-in / external) |
| Ingress protection | IP21 |
| Operating temperature | −10 °C to 60 °C |
| Relative humidity | 5%–95% (non-condensing) |
| Storage temperature | −15 °C to 65 °C |
| Max. operating altitude | 4000 m (derating above 2000 m) |
Application & Selection
Solar and battery energy systems. Check AC supply voltage, PV string open-circuit voltage, battery current and the supplied configuration before selection.