PV15000-48 S12.0 Solar Inverter
12kW, 48V battery and two MPPT inputs in a single-unit configuration; battery-only 10kW at 50V.
- MPPT photovoltaic input
- Battery-based energy storage and backup configuration
- Pure sine-wave AC output
PV15000-48 S12.0 Solar Inverter
12kW, 48V battery and two MPPT inputs in a single-unit configuration; battery-only 10kW at 50V.
Product features
- MPPT photovoltaic input
- Battery-based energy storage and backup configuration
- Pure sine-wave AC output
Applications
Solar and battery energy systems. Check AC supply voltage, PV string open-circuit voltage, battery current and the supplied configuration before selection.
Selection & configuration
Match the exact ordering model to the supply, load and site conditions. Consult the model-specific technical data before choosing PV strings, motor equipment or battery settings.
Model rating table
↔ Scroll left or right on small screens to view every column. Focus the table region to use the arrow keys.
| Model | Rated output | Rated AC current | AC output voltage | Battery | Max. PV input power | Max. PV Voc | MPPT range | Max. PV input current | Max. PV charge current | Max. parallel units | IP rating |
|---|---|---|---|---|---|---|---|---|---|---|---|
| PV15000-48 S12.0 | 12 kVA / 12 kW | 52.2 A | 220/230/240 V (rated 230 V) | 48 V (40–60 V) | 15000 W (2 strings total) | 500 V DC | 60–450 V DC | 27 A + 27 A | 160 A | Not available on the single-unit version | IP21 |
AC input
| Rated input voltage | 220/230/240 V; L+N+PE |
|---|---|
| Input voltage range | 90–280 V (APP/GEN mode); 170–264 V (UPS mode) |
| Input frequency | 50/60 Hz (auto adaptive) |
| Max. AC bypass current | 70 A |
AC output
| Rated capacity | 12 kVA / 12 kW (AC output 1 max 70 A; AC output 2 max 40 A) |
|---|---|
| Surge power | 24 kVA |
| Output voltage | 220/230/240 V |
| Rated output current | 52.2 A |
| Power factor | 1 |
| Output frequency | 50/60 ±0.1% |
| Transfer time | 10 ms (APP/UPS mode) / 20 ms (GEN mode) |
| Waveform | Pure sine wave |
| Overload capacity (PV+battery / PV mode) | 1 min @ 102–125% load; 10 s @ 125–200% load |
| Max. efficiency (battery mode) | 94% @ 48 V |
PV / charger
| Solar charger type | MPPT |
|---|---|
| Max. PV input current / power | Single PV input 27 A / 9000 W; dual PV input 27 A + 27 A / 15000 W total |
| MPPT operating range | 60–450 V DC |
| PV start-up voltage | 80 V DC |
| Max. PV open-circuit voltage | 500 V DC |
| Max. PV charge current | 160 A |
| Max. AC charge current | 160 A |
| Max. charge current (PV+AC) | 160 A |
Battery
| Nominal battery voltage | 48 V DC (range 40–60 V) |
|---|---|
| Battery type | Lithium / lead-acid |
Derating
| Max. load, battery only | 10000 W @ 50 V |
|---|---|
| Max. load, PV + battery | 12000 W |
General
| HMI | LCD |
|---|---|
| Monitoring | Wi-Fi (optional) |
| Ingress protection | IP21 |
| Operating temperature | −10 °C to 60 °C |
| Relative humidity | 5%–95% (non-condensing) |
| Max. operating altitude | 4000 m (derating above 2000 m) |
| Safety class | I |
| Interface | RS232 / RS485 / CAN (single-unit version, no parallel ports) |
| Max. parallel units | Not available on the S12.0 single-unit version |